U.S. flag

An official website of the United States government, Department of Justice.

Technical note: Measuring Bicondylar Length in Computed Tomography Data

NCJ Number
309596
Journal
American Journal of Biological Anthropology Dated: October 2024
Date Published
October 2024
Annotation

This paper describes the research materials, methodology, and results of an effort to develop detailed protocols for measuring bicondylar length of the femur using three different imaging software programs: 3D Slicer™, Amira™, and Simpleware™; the goal for these protocols is to provide researchers and practitioners in radiology, orthopedics, biomechanics, and biological anthropology with accurate and reproducible measurement techniques.

Abstract

With the increased use of 3D-generated images in biological research, there is a critical need to adapt classical anatomical measurements, traditionally conducted with calipers, to a virtual environment. We present detailed protocols for measuring bicondylar length, a critical dimension of the femur, using three different imaging software programs—3D Slicer™, Amira™, and Simpleware™. These protocols provide researchers and practitioners in radiology, orthopedics, biomechanics, and biological anthropology with accurate and reproducible measurement techniques. The objective is to standardize and support virtual osteology in biomechanical research, stature estimation, and related medical and anthropological studies. Adhering to standardized protocols, we adapted femoral bicondylar length measurements for computed tomography images from a New Mexican collection (n = 10). The method was designed for applicability and reproducibility across three software platforms. By comparing measurements from the same sample across different observers and different platforms, this study validates the accuracy and consistency of the adapted protocol, demonstrating its utility for research and clinical assessments. The authors present a step-by-step guide for each program, detailing bone alignment and measurement. They illustrate each step and provide video tutorials via links for an enhanced understanding of the process. Bicondylar length can be measured effectively in each software program following the provided instructions. However, ease of measurement varied among the programs, with some offering a more straightforward process. This variability underscores the importance of choosing appropriate software for the user's needs and proficiency. It also suggests areas for improvement and standardization in software design and instructional clarity. (Published Abstract Provided)

Date Published: October 1, 2024