This research project evaluated the performance of the conventional methods used in forensic analysis of adhesive tapes (physical and microscopic examination, FTIR, Py-GC-MS, and SEM-EDS) and the more recently developed elemental methods, LIBS and LA-ICP-MS, for the comparison of tape samples in different laboratories.
Two interlaboratory exercises were designed to study the performance of the different analytical methods for the forensic analysis of electrical tapes. The exercises were developed with the objective to imitate forensic case scenarios where known and question tapes are compared following the laboratory's analytical protocol. The participants were asked to compare the tape samples as in a regular forensic case. Seven laboratories participated in the two interlaboratory exercises. All the laboratories performing SEM-EDS in both interlaboratory exercises (#1 and #2) were able to correctly associate the pairs of tapes originating from the same rolls, therefore the rate of false negatives was zero. Two of the laboratories performing SEM-EDS for the first interlaboratory exercise incorrectly associated two pairs of tapes belonging to different rolls, resulting in a 17 percent false positive rate. One of the laboratories performing SEM-EDS for interlaboratory exercise #2 incorrectly associated two pairs of tapes belonging to different rolls, resulting in a 13 percent false positive rate. Up to 7 and 8 elements were detected by SEM-EDS for interlaboratory exercise #1 and #2, respectively. The increased sensitivity and selectivity of LIBS and LA-ICP-MS methods allowed to distinguish all the pairs of tapes originating from different sources and for correctly associate the tapes originating from the same rolls, resulting in no false positives or false negatives. In addition, increased characterization of the samples was obtained by detecting up to 14 elements by LIBS and 27 elements by LA-ICP-MS for interlaboratory exercise #1, and 17 elements by LIBS and 32 elements by LA-ICP-MS for interlaboratory exercise #2. A match criterion of +/- 5s allowed to numerically compare LIBS ratios and LA-ICP-MS signal areas for a more objective assessment of the differences between the tape samples. (publisher abstract modified)
Downloads
Similar Publications
- The Accumulated Impact of Critical Incident Exposure on Correctional Officers' Mental Health
- Trauma Behind the Keyboard: Exploring Disparities in Child Sexual Abuse Material Exposure and Mental Health Factors among Police Investigators and Forensic Examiners – A Network Analysis
- Addressing the Challenges of Detecting Drug-Facilitated Sexual Assault