U.S. flag

An official website of the United States government, Department of Justice.

Electrophoretic Injection within Microdevices

NCJ Number
311155
Journal
Analytical Chemistry Volume: 74 Issue: 9 Dated: 2002 Pages: 1952-1961
Date Published
April 2002
Length
10 pages
Abstract

The flexibility of the microfabricated format creates unique opportunities for study of the electrophoretic process. The present work utilizes digital images to capture the motion of DNA samples during pre-electrophoretic processes. A systematic study of DNA loading and strong sample stacking (sample concentration effects) was performed in order to analyze realistic DNA analysis conditions within microdevices. Using digital imaging and microscopy, DNA sample profiles within the injector were analyzed by deconvolving the geometrical intensity profile into different velocity groups. This analysis illustrates the evolution of molecular separation into distinct migrating populations within the injector itself. The present study performed DNA injections within microfabricated devices imposing run voltages between 85 and 850 V/cm. Data from 3 different offset lengths of a double-T cross-injector, 10 different applied voltages, and 2 different sample preparation protocols are presented.

(Publisher abstract provided.)

Date Published: April 1, 2002